---------------------------------------------------------------------------------------------------- >>>>>>>>>>>>>>>>>>>>>>>>>>> STATION-CHECK RESULTS for last 1 checks <<<<<<<<<<<<<<<<<<<<<<<<<<< ---------------------------------------------------------------------------------------------------- ================== = csv -- (last) = ================== -- Station name : FR606C -- Check runtime : 07-08-2018 21:00:00 .. 07-08-2018 21:09:08 -- Checks done : RSP-firmware-version, TB-firmware-version, TB-memory-check : SPU-board-check, RSP-board-checks, TB-board-checks -- Checks done M3 : Short, Flat, Down, RF, Oscillation, Spurious, Noise[60sec] -- Checks done M5 : Modem, Oscillation, Spurious, Summator-noise, Noise[60sec] -- Bad antennas : LBH=1 HBA=1 == TBB ============================================================================================ Board 8 wrong firmware version: TP=na MP=na Board 8 Memory address or dataline error Board 8 wrong voltage: 1.2V=0.00 2.5V=0.00 3.3V=0.00 == LBA High ======================================================================================= X test done with subband=301 and ref.signal=82.6dB Y test done with subband=301 and ref.signal=82.0dB Antenna 74, RCU 149, Y RF fail: signal=78.4dB == HBA ============================================================================================ -- Tile 12 (RCU 24/25) --------------------------------------------------------------------------------- Y Summator noise